Paddle type flow switch for liquids, with flow indicator,
for max. or min. flow alarm, with a single switching unit, with output on SPDT
switch. TECHNICAL DATA • horizontal mounting • single switching unit (on
request, two SPDT switches with simultaneous action can be supplied) • set
point can be adjusted to between 10 ÷ 60% of max. flow rate (Q). • fixed
differential for each set point with value variable between 20 ÷ 50% of max.
flow rate (Q) • accuracy of flow indication: ± 15% of f.s • calibrating liquid:
water • set point accuracy ± 5% of max. flow rate (Q) • max. temperature 130˚C
• max. pressure 10 Bar • max. Pressure drop 500 mm H2 O • gaskets in neoprene